Thermometers reading different temperatures on cold printer?
I am in the process of buttoning up a Nitehawk conversion on my Voron. I also replaced my extruder thermistor with an OE replacement purchased from a reputable vendor.
Post setup, my heated bed is reading spot on (it's 18.3 C in my basement aka 65 F). I verified that my extruder is also at ambient temperature by wedging a Thermapen under its silicone sock and letting it acclimate for 10 minutes. The I'm not sure why the extruder would be reading high.
I bought a spare thermistor and wired it in. The result was identical.
Thoughts? Ideas? I'm pretty sure I have the Nitehawk and thermistor set up correctly.
They're 104nt's. I have never calibrated a thermistor for one of my printers before, other than updating the firmware (compile marlin, config Klipper) and choosing the appropriate value.
I did dig up a datasheet for the thermistor, will have to check resistance tonight.
Oh, that ` was me fighting with markdown to get the code portion of the post nicely formatted. I couldn't figure out newlines and gave up.
I don't think heat is getting to the extruder via the NH. The thermistor is potted in a m3 bung that's threaded into the extruder. The extruder itself is at ambient a few mm away.
This is what my temps look like after letting the printer cool back down again:
It's a LDO Voron2.4 kit with the stock Extruder and the nitehawk board. The chamber thermistor sits on top of the stealth burner side door.
I dislike Discord as much as the next, but have you tried asking around if someone else has the same issue? Maybe you got unlucky and your nighthawk is defective.
My voron with can toolhead, using a pt1000, I'd accept +/- a degree or so but that's a bit more than that. Could trying calibrating the pullup value manually? I'm using Generic 3950 for the sensor types on the Semitec 100k thermistors (chamber temp and plate temp are both using one of those), had the best results with that personally, could see if that helps things.
Agree that this seems like a bigger than desired difference.
Thanks for the point of reference. I am going to be doing some measuring and math tonight to try to figure out where the source of error is and how much it might/not matter when hot.
Before nitehawk I was using the same hot end and I copied the thermistor type from my prior config while setting up. The bed and extruder were much closer to each other when cold then.
It's the same thermistor value that I was using previously, but I did replace the thermistor when I installed the NH. This means I'm guilty of changing two things at once, which makes attributing cause hard.
I ran my first prints after the NH install yesterday and all went well, so I'm going to file this in an OCD annoyance vs something I need to worry about.